UTAR Institutional Repository

Vapor Chamber Embedded With Hollow Condenser Tubes Heat Sink.

Goh, Wen Qian (2017) Vapor Chamber Embedded With Hollow Condenser Tubes Heat Sink. Final Year Project, UTAR.

[img]
Preview
PDF
Download (1697Kb) | Preview

    Abstract

    A novel vapor chamber with embedded hollow condenser tubes heat sink was designed and fabricated. Experiments were carried out to determine its thermal performance. The device was used to improve the thermal management of electronic packages. In this study, two vapor chambers heat sinks were tested using different fill ratios. Natural and forced convection as cooling model were employed and subjected to two different power inputs of 10W and 20W. The results of this investigation showed that, Force Convection performs better with lower thermal resistance compared to Natural Convection, Under Natural Convection, lower Fill Ratio (FR=0.5) performs better, Under Forced Convection, higher Fill Ratio (FR=1.0) performs better, Under Natural Convection, lower Fill Ratio does not affect the performance of Vapor Chamber #1 & Vapor Chamber #2 and Under Forced Convection and at low Fill Ratio, Vapor Chamber #2 performs better than Vapor Chamber #1.

    Item Type: Final Year Project / Dissertation / Thesis (Final Year Project)
    Subjects: T Technology > TA Engineering (General). Civil engineering (General)
    Divisions: Faculty of Engineering And Green Technology > Bachelor of Engineering (Honours) Industrial Engineering
    Depositing User: ML Main Library
    Date Deposited: 20 Oct 2017 15:59
    Last Modified: 27 Aug 2019 17:38
    URI: http://eprints.utar.edu.my/id/eprint/2581

    Actions (login required)

    View Item